Chapter 3
Changing Symbology Settings
3.10 GS1-128 (EAN-128)
*Enable
Disable
Note: When this setting is disabled, GS1-128 barcodes used to be taken as Code 128.
However, starting from firmware version 1.10, GS1-128 barcodes can be decoded
only when this setting is enabled.
3.10.1 TRANSMIT CODE ID
Decide whether to include the Code ID ("]C1") in the data being transmitted.
Transmit Code ID
*Do Not Transmit
3.10.2 FIELD SEPARATOR (GS CHARACTER)
Decide whether to apply a field separator (to convert the FNC1 control character to human
readable character).
Enable Field
Separator…
1) Read the barcode above to enable field separator.
2) Read the “
Hexadecimal Value” barcode on page 158 for the desired character string.
3) Read the “Validate” barcode to complete this setting.
Note: GS1-128 barcodes start with the
FNC1 control character to distinguish themselves
from other uses of Code 128. FNC1 is also used to separate data fields in the
GS1-128 barcodes.