23
Chapter 2 Barcode Settings
Check Code Length
By default, the maximum barcode length is 15. Select the check box so that it will perform a
length check on the barcode according to the length setting. When the barcode is found longer
than the specified length, it will be discarded.
Read Partial Barcode
By default, it will return the whole barcode that has been decoded. Select the check box so that it
will return partial barcode according to the settings of the start position and maximum length.
Below are some examples.
Start position Max. length Barcode scanned Transaction record
2 10 9876543210 876543210
2 3 9876543210 876
Read partial code + Check leading code:
Start position Max. length Leading Code Barcode scanned Transaction record
2 7 8 9876543210 8765432
2 7 9 987654321 (Discarded)
2.3.2 SCANNER
Always Enable After Login
The barcode reader is always enabled after login because the scan engine detected is enabled by
default.
Controlled by ESC Command
If selected, the barcode reader is suspended and must be controlled by ESC commands. Instead of
using the default ESC commands or special commands, you may specify an ESC command
in the
following format — ESC then left bracket, followed by two numeric
characters, and must end with a
lower-case letter (a ~ z).
Option Escape Sequence
Enable You need to send one of the following ESC commands to enable it:
Instead of the default ESC[99h, specify an ESC command if necessary.
Special ESC Command — ESC[2;1]
Disable To stop it from working, send one of the following ESC commands:
Instead of the default ESC[99l, specify an ESC command if necessary.
Special ESC Command — ESC[2;0]
Auto Enter
You may also specify an escape sequence for automatically adding a
carriage return to the end of each scan (= Scan+ENTER).
Ignore this option if you already have the Auto Enter function enabled for
data processing. Refer to 2.3.3 Data.
Comentarios a estos manuales