Enter Setup
1500/1502 Barcode Scanner User Guide
2.2.5 STOP BIT
2.2.6 FLOW CONTROL
By default, there is no flow control in use. Select the flow control (handshake) method.
Options
Description
No No flow control
Scanner Ready
T
he scanner will activate the RTS signal upon powering on. After each good
read, the scanner will then wait for the CTS signal to become active. Data
will not be sent until the CTS signal becomes active.
Data Ready The RTS signal will be activated after each good read. The scanner will then
wait for the CTS signal to become active. Data will not be sent until the CTS
signal becomes active.
Inverted Data Ready It works the same as the Data Ready flow control, except that the RTS
signal level is inverted.
Odd
2 stop bits
*
1 stop bit
*None
S
canner Ready