CipherLab 1266 Manual de usuario

Busca en linea o descarga Manual de usuario para Lectores De Códigos De Barras CipherLab 1266. CipherLab 1266 User`s manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 55
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
1166/1266 Bluetooth Wireless Scanners
User’s Manual
Document Number: 1X66-1
Release Date: Dec. 2005
2005, SYNTECH INFORMATION Co., Ltd..
All rights reserved. CipherLab is a registered trademark of SYNTECH
INFORMATION Co., Ltd.
WARNING
This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to Part 15 of FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try correct the
interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
If applicable, as below
FCC Caution: To assure continued compliance, (example – use only shielded
interface cables when connecting to computer or peripheral devices). Any changes
or modifications not expressly approved by the party responsible for compliance
could void the user’s authority to operate this equipment.
This transmitter must not be co-located or operating in conjunction with any other
antenna or transmitter.
FCC Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
minimum distance 20 cm between the radiator & your body.
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that
may cause undesired operation.
Vista de pagina 0
1 2 3 4 5 6 ... 54 55

Indice de contenidos

Pagina 1 - User’s Manual

1166/1266 Bluetooth Wireless Scanners User’s Manual Document Number: 1X66-1 Release Date: Dec. 2005  2005, SYNTECH INFO

Pagina 2 - Table of Contents

13131313 4.2 RS232 Interface User can select the desired, flow control, baud rate, parity, and data bits to be used in this output interface. 4.2.1

Pagina 3

15151515 5. Bluetooth Serial Port The 1166/1266 can be configured to the standard Bluetooth Serial Port as the data output interface. This will mak

Pagina 4 - 1. Introduction

17171717 3. Check My device is set up and ready to be found and click Next button. 4. Select 1x66 scanner and click Next button for next step. 6

Pagina 5 - 2. 3666 Installation

19191919 3. Select Client Applications tab and select Bluetooth Serial Port from the list then click Property button. 4. Check Secure Connection if

Pagina 6 - 2.5 Interface Setting

21212121 8. Click OK button. After successful connection

Pagina 7 - 3. General Features

23232323 6.1.3 Authentication & PIN Code The 1x66 scanner can do connection authentication if communication security is desired. Once this setti

Pagina 8 - 3.9 Negative Barcodes

25252525 6.3 Configuring Bluetooth Device Driver Please follow the procedures below to configure the Bluetooth driver on the host system. Please no

Pagina 9

27272727 8. The scanner is ready to use. Please click OK button. 6.3.2 Widcomm Bluetooth Driver 1. Click icon at PC. 2. Click Find Bluetooth

Pagina 10 - 4.4 Memory Parameters

29292929 8. When the green arrow icon is displayed, the connection is ready. 30 7. Symbology Parameters This section describes user con

Pagina 11 - 5. Bluetooth Serial Port

31313131 • Checksum Transmission: This parameter specifies whether the checksum character is included in the data being transmitted. • Code L

Pagina 12

Table of Contents REVISION HISTORY...1 1. INTRODUCTION...

Pagina 13

33333333 • Checksum Verification: Three kinds of checksum calculations can be implemented into MSI code: Single Modulo 10, Double Mod

Pagina 14 - 6. Bluetooth HID

35353535 8. Data Output Format Data read by the scanner will be processed in the following sequence (RS-232, Keyboard Wedge and USB int

Pagina 15 - Keyboard

37373737 9. Data Editing The 1166/1266 scanner provides advanced data editing functions for data formatting. Data editing is performed acc

Pagina 16

39393939 always included in the field. User though, has the option of discarding this terminating string. • Field Length: The field division can be

Pagina 17

41414141 10. Configuring your 1166/1266 The configuration of 1166/1266 Scanner is done by reading the setup labels contained in the C

Pagina 18 - 7. Symbology Parameters

43434343 The available key type/status settings can be selected will be described briefly. The configuration procedures for character string paramete

Pagina 19

1166/1266 Bluetooth Wireless Scanners User’s Manual Document Number: 1X66-2 Release Date: Dec. 2005  2005, SYNTECH INFORMAT

Pagina 20 - 7.12 RSS

RSS14 Parameters...37 RSS Limited Parameters ...

Pagina 21 - 8. Data Output Format

1 Update Restore Default Settings Exit Setup without Changes Set Connection * Programming Instructions: (1) Read the label. (2) Read t

Pagina 22 - 9. Data Editing

3 Update List Setting Page1 Page 6 Page 2 Page 7 Page 3 Page 8 Page 4 Page 9 Page 5 Page 10 Buzzer Settings <

Pagina 23

7.8 EAN13 ...32 7.9 MSI ...

Pagina 24 - 10.3 List Setting

5 Update Scanner Time-out Duration * Programming Instructions: (1) Read the label. (2) Program the desired time-out duration by reading Decimal Digi

Pagina 25 - "Validate" Label

7 Update • Keyboard Alphabets Layout < Default Layout > AZERTY QWERTZ • Keyboard Digits Layout < Default Layout >

Pagina 26

9 Update RS-232 Parameters • Activate RS232 Interface • Baud Rate 115200 38400 11920

Pagina 27 - Revision History

11 Update Bluetooth Serial Port Parameters • Activate Bluetooth Serial Port Interface • Device Name Broadcasting < Yes > No • Authe

Pagina 28 - • Memory Data Delay

13 Update • Authentication Yes < No > • PIN Code * Programming Instructions: (1) Read the label. (2) Program the desired character

Pagina 29 - Auto-Sense Setting

15 Update Prefix / Postfix Settings Prefix Code * Postfix Code * Character Substitution Set 1 * Set 2 * Set 3 * Programming In

Pagina 30 - Keyboard Wedge Parameters

17 Update Length Code Setting (2 digits) • Code 39 Length Code Enable < Disable > • Italy Pharmacode Length Code Enable <

Pagina 31

19 Update • Code 93 Length Code Enable < Disable > • Code 128 Length Code Enable < Disable > • EAN128/RSS Length Cod

Pagina 32 - RS-232 Parameters

21 Update • Matrix 25 Enable < Disable > • Codabar < Enable > Disable • Code 93 < Enable > Disable •

Pagina 33 - Bluetooth HID Parameters

23 Update • UPCE < Enable No Addon > Disable No Addon Enable Addon2 < Disable Addon2 > Enable Addon5 < Disable A

Pagina 34

1111 Revision History Version Release Date Notes V 1.00 Oct. 31, 2005 First release. V 2.00 Dec. 30, 2005 Supports Bluetooth HID. Firmware vers

Pagina 35 - Code ID Setting

25 Update Code39 Parameters • Standard / Full ASCII Code39 < Standard > Full ASCII • Start / Stop Transmission Enable <

Pagina 36

27 Update • Max / Min Code Length Qualification Select Max / Min Length Qualification Max Length * Min Length * • Fixed Code Length Qualif

Pagina 37 - Select Readable Codes

29 Update • Fixed Code Length Qualification Select Fixed Length Qualification Fixed Length 1 * Fixed Length 2 * Programming Instructions:

Pagina 38

31 Update Start / Stop Selection < abcd / abcd > abcd / tn*e ABCD / ABCD ABCD / TN*E Plessey Parameters • Convert to UK Plessey

Pagina 39

33 Update • Fixed Code Length Qualification Select Fixed Length Qualification Fixed Length 1 * Fixed Length 2 * Programming Instructions:

Pagina 40 - Industrial 25 Parameters

35 Update UPCE Parameters • System Number Selection System Number 0 and 1 < System Number 0 only > • Convert to UPCA Enable

Pagina 41 - Interleave 25 Parameters

37 Update RSS Code ID Selection ]C1 < ]e0 > RSS14 Parameters • Code ID Transmission < Enable > Disable • Applicat

Pagina 42 - Codabar Parameters

39 Update Activate Editing Formats • Format 1 Enable < Disable > • Format 2 Enable < Disable > • Format 3 Enable

Pagina 43 - MSI Parameters

41 Update • Applicable Data Length Maximum Length * Minimum Length * Programming Instructions: (1) Read the label. (2) Program the desired

Pagina 44 - UPCA Parameters

43 Update • Applicable Code Type All Clear Code 39 Italy Pharmacode French Pharmacode Industrial 25 Interleave 25 Matrix 2

Pagina 45 - EAN13 Parameters

3333 2. 3666 Installation The 1166/1266 kit contains: A 1166/1266 wireless barcode scanner A 3666 base A rechargeable battery A Serial/Keyboard/US

Pagina 46 - RSS Expanded Parameters

45 Update • Field1 Setting Divide Field by Field Terminating String Field Terminating String * Programming Instructions: (1) Read the label.

Pagina 47 - Editing Format Parameters

47 Update • Field3 Setting Divide Field by Field Terminating String Field Terminating String * Programming Instructions: (1) Read the label. (2) P

Pagina 48 - • Total Number of Fields

49 Update • Field5 Setting Divide Field by Field Terminating String Field Terminating String * Programming Instructions: (1) Read the label. (2) P

Pagina 49 - • Applicable Code Type

51 Update • Field Transmission Sequence Start Field 1 Additional Field 1 Field 2 Additional Field 2 Field 3 Additional Field 3

Pagina 50 - • Field2 Setting

53 Update Hexadecimal Digits 0 8 1 9 2 A 3 B 4 C 5 D 6 E 7 F • Validate 54 Enter Setup Key Type

Pagina 51 - • Field4 Setting

55 Update KBD Wedge Character Table 0 1 2 3 4 5 6 7 8 0 F2 SP 0 @ P ` p  1 Ins F3 ! 1 A Q a q  2 Del F4 " 2 B R b r  3 Home F5 # 3 C S c

Pagina 52 - • Additional Fields Setting

5555 2.4 Charging your 1166/1266 There are three methods to charge the battery. One is placing the scanner on the base and another is inserting the

Pagina 53 - Decimal Digits

7777 3. General Features 3.1 Buzzer The buzzer of the scanner beeps differently to indicate various operating conditions. • Power On Beep: The

Pagina 54 - Key Status

9999 3.5 Re-read Delay If the scanner mode is set to Continuous, Auto Power Off, Alternate, or Momentary mode, the scanner will prevent accide

Pagina 55 - RS-232 Character Table

11111111 4. Output Interface (3666 Base Unit) The 1166/1266 is a multi-interface scanner. It can be used as a keyboard wedge scanner,

Comentarios a estos manuales