ScanManager User Guide
By default, it is set no parity bit. Select other parity setting, even or odd parity bit.
By default, there is no flow control in use. Select the flow control (handshake) method.
No No flow control
Scanner Ready The scanner will activate the RTS signal upon powering on. After each good
read, the scanner will then wait for the CTS signal to become active. Data
will not be sent until the CTS signal becomes active.
Data Ready The RTS signal will be activated after each good read. The scanner will then
wait for the CTS signal to become active. Data will not be sent until the CTS
signal becomes active.
Inverted Data Ready It works the same as the Data Ready flow control, except that the RTS
signal level is inverted.
2.2.6 INTER-CHARACTER DELAY
By default, the inter-character delay is set to zero. Enter a value, ranging from 0 to 255
in units of millisecond, to match the computer response time of the RS-232 interface.
Such delay time is inserted between every character being transmitted. The longer the
delay time is, the slower the transmission speed will be.