38
ScanManager User Guide
3.2 CODE 25 — INDUSTRIAL 25
By default, the scanner is set to read Industrial 25 barcodes.
Advanced settings are provided as shown below.
Select a desired start/stop pattern. For example, flight tickets actually use an Industrial 25
barcode but with Interleaved 25 start/stop pattern. In order to read this barcode, the start/stop
pattern selection of Industrial 25 should set to Interleaved 25.
Decide whether to verify check digit when decoding Industrial 25 barcodes. If the check digit is
incorrect, the barcode will not be accepted.
The check digit will be included in the data being transmitted.
Cancel the check box if the check digit is not desired.
Because of the weak structure of the 2 of 5 barcodes, it is possible to make a "short scan" error.
To prevent the "short scan" error, configure the "Length Qualification" settings to ensure that the
correct barcode is read by qualifying the allowable code length. The barcode can be qualified by
"Fixed Length" or "Max/Min Length".
For "Fixed Length", up to 2 fixed lengths can be specified.
For "Max/Min Length", the maximum length and the minimum length must be specified. The
scanner will only accept those barcodes with lengths that fall between max/min lengths
specified.