Chapter 3
Changing Symbology Settings
3.16.1 FOR 1D SCANNERS
Select the check box so that the scanner can read GS1 DataBar (also known as RSS)
barcodes.
Advanced settings are provided as shown below.
GS1 DataBar (RSS Family)
Select the check box to enable at least one group of the GS1 DataBar barcodes.
GS1 DataBar Omnidirectional & Expanded for Groups I and II
GS1 DataBar Limited for Group III
Code ID Selection
By default, the Code ID of GS1 DataBar (RSS) barcodes is “]e0”. You may select to use “]C1”
instead.
“]C1” is the Code ID of GS1-128 (EAN-128) barcodes.
Transmit Code ID
The selected Code ID will be included in the data being transmitted.
Cancel the check box if the Code ID is not desired.
Transmit Application ID
The Application ID will be included in the data being transmitted.
Cancel the check box if the Application ID is not desired.
GS1 DataBar Omnidirectional
A
lso known as RSS-14
A
lso known as RSS Limited
A
lso known as RSS Ex
p
anded