61
Chapter 2
Selecting Output Interface
2.5.2 DEVICE NAME BROADCASTING
Device Name Broadcasting is selected by default. Deselect it to hide the scanner from
other Bluetooth
®
-enabled
devices such as PC or PDA. However, broadcasting must be
enabled for establishing an initial connection with other Bluetooth
®
-enabled
devices.
For example, you can disable device name broadcasting after successfully connecting the
scanner to WorkStation1. Such connection will be maintained automatically unless the
scanner is removed from the paired device list (called unpairing) by WorkStation1 or any
changes made to authentication and the PIN code. If you want WorkStation2 to connect
to the scanner, you have to enable device name broadcasting first.
Note: Device Name Broadcasting is selected by default (as it is required for initial
connection).
2.5.3 SNIFF MODE
This power-saving feature is selected by default for 1560/1562/1564/1660/1661/1664,
meaning the scanner will listen to the wireless network at a reduced rate.
Note: When connecting more than two scanners to a notebook computer or PDA with
Bluetooth
®
wireless technology, we suggest that you disable the power-saving
setting for a more reliable connection.
2.5.4 INTER-FUNCTION DELAY
By default, the inter-function delay is set to zero. Enter a value ranging from 0 to 254 by
the unit of millisecond to match the computer response time of the RS-232 interface.
Such delay time is inserted between every function code (0x01 ~ 0x1F) being transmitted.
The longer the delay time is, the slower the transmission speed will be.
2.5.5 ACK/NAK TIMEOUT
By default, the scanner sends data to the host without waiting for an ACK/NAK response
before sending more data. Set a value ranging from 1 to 99 by the unit of 0.1 second for
the time that the scanner waits for the host computer’s ACK/NAK response. If no
response is received before the specified timeout, the scanner will attempt to send the
same data three more times. If all attempts fail without any notification, data loss will
occur.
Note: We suggest that you enable the error beep so that you will be notified of such data
loss and have the scanner re-read the data.