84
ScanMaster User Guide
3.6 CODE 93
3.6.1 FOR 1D SCANNERS
By default, the scanner is set to read Code 93 barcodes.
No advanced settings are available.
3.6.2 FOR 2D SCANNERS
By default, the scanner is set to read Code 93 barcodes.
Advanced settings are provided as shown below.
Length Qualification
To prevent the "short scan" error, define the "Length Qualification" settings to ensure that the
correct barcode is read by qualifying the allowable code length. The barcode can be qualified by
"Fixed Length" or "Max/Min Length".
For "Fixed Length", up to 2 fixed lengths can be specified.
For "Max/Min Length", the maximum length and the minimum length must be specified. The
scanner will only accept those barcodes with lengths that fall between max/min lengths
specified.