Chapter 3
Changing Symbology Settings
Length Qualification
To prevent the "short scan" error, define the "Length Qualification" settings to ensure that the
correct barcode is read by qualifying the allowable code length.
T
he barcode can be qualified by
"Fixed Length" or "Max/Min Length".
For "Fixed Length", up to 2 fixed lengths can be specified.
For "Max/Min Length", the maximum length and the minimum length must be specified. The
scanner will only accept those barcodes
with lengths that fall between max/min lengths
specified.