ScanMaster User Guide
Data Length
The length must include prefix, suffix (0x0d by default), length code, etc. By default, barcodes
with length (character count) ranging from 0 to 127 are eligible for data editing.
Enter a value from 0 to 254.
When zero is given to both, the scanner will not perform the length qualification.
Matching String & Location
By default, no matching string is entered, and therefore, it is disabled. You may enable this
feature by entering a matching string. Choose up to four characters from the pop-up window of
Grid Control. Refer to
Appendix I Grid Control.
When the Matching String Location is zero, the scanner will only check for the existence of the
matching string in the barcode data.
Enter a value from 1 to 254 to indicate where the matching string starts in the barcode data.