CipherLab 1562 Guía de usuario Pagina 88

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 160
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 87
76
ScanMaster User Guide
3.2.2 FOR 2D SCANNERS
By default, the scanner is set to read Industrial 25 barcodes.
Advanced settings are provided as shown below.
Length Qualification
Because of the weak structure of the 2 of 5 barcodes, it is possible to make a "short scan" error.
To prevent the "short scan" error, configure the "Length Qualification" settings to ensure that the
correct barcode is read by qualifying the allowable code length. The barcode can be qualified by
"Fixed Length" or "Max/Min Length".
For "Fixed Length", up to 2 fixed lengths can be specified.
For "Max/Min Length", the maximum length and the minimum length must be specified. The
scanner will only accept those barcodes with lengths that fall between max/min lengths
specified.
Vista de pagina 87
1 2 ... 83 84 85 86 87 88 89 90 91 92 93 ... 159 160

Comentarios a estos manuales

Sin comentarios