63
Chapter 2
Selecting Output Interface
Note: In SPP Master Mode, if it fails to re-connect within the specified period of time (2
minutes by default), the scanner will become inactive to save power. Once the
re-connection is established successfully, the scanner will not go through transition
from full CPU speed to low CPU speed even though it is idle during the specified
time interval for Auto Power Off. It will automatically turn off when the time is up.
Refer to
1.2 Power Management (1560/1562/1564/1660/1661/1664).
How to connect with the target device?
Produce two setup barcodes for the target SPP slave device, just like what we do for 3610 or
3656.
“Set Connection” barcode
“MAC Address” barcode
Usage:
1. Change the interface to Bluetooth SPP Master and download settings to the scanner.
2. Click the field of “MAC Address of Remote Device” to choose characters from the pop-up
window of Grid Control (see Appendix I
Grid Control). It requires 12 characters.
3. Click [OK] to complete all the settings.
4. Go to Download | Print scanner settings to produce the “Set Connection” and “MAC
Address” barcodes for printout.
5. Have the scanner read the “Set Connection” and “MAC Address” barcodes. It will respond
with one beep upon reading each of the barcodes.
Note: (1) It will automatically add a prefix of “0x” to the real MAC address of the target
device.
(2) Read the “Set Connection” barcode first, and then the “MAC Address” barcode
within 10 seconds.
Switch between Master/Slave Mode
After the scanner has established a connection as a SPP slave device, change the interface to
Bluetooth SPP Master and download settings to the scanner. It will work as a SPP master device
then.
Note: Switching from SPP Slave to SPP Master does not require a new PIN code. You
must leave it blank or enter exactly the same PIN code for SPP Slave; otherwise, it
will fail to resume connection if a different PIN code is specified.
Exit SPP Master Mode
To stop re-connection, change the interface to Bluetooth SPP Slave and download settings to the
scanner. Alternatively, you may have the scanner read “Reset Connection” or “Restore System
Defaults” barcode so that the current connection record (= MAC Address) will be cleared. Then,
the scanner will restart itself automatically. Refer to a separate manual for instructions.